Application area:
It is suitable for molecular biology, protein, DNA, RNA, blood component separation and cell component separation, and is widely used in clinical medicine, life science, bioengineering, biochemistry, medical research, agriculture and animal husbandry, biopharmaceutical and other fields.
Product features:
1. Steel body, large torque brushless AC frequency conversion motor drive: no toner pollution, low noise, small vibration, high speed control accuracy.
2. Program 7-inch color touch screen display: speed, centrifugal force, running time, rotor number and details, lifting rate, etc.; with touch screen lock function to prevent misoperation.
3. Built-in 10 kinds of up / down gear, can be customized according to the experimental requirements, to ensure the good centrifugal effect.
4. Adopt imported high-efficiency and environment-friendly refrigeration system, intelligent pre-cooling, fast refrigeration speed, low noise, high temperature control accuracy, and optional heating module.
5. It can be high-speed centrifugation (22000 r/min), and large capacity centrifugation (4750ml), one machine is multi-function.
6. With the diagnostic functions such as door cover and misoperation, the machine can directly display the fault information, which is easy to judge and repair, and ensure the safety of man and machine.
Company Name :
Hunan Anjunyan Instruments Co., Ltd.Brand :
ANJUNYANTechnical parameter:
1. Maximum rotation speed: 22,000 r/min
2. Maximum centrifugal force: 35,713×g
3. Maximum capacity: 4×750 ml
4. Speed accuracy: ±10r/min
5. Temperature setting range:-20℃ - + 40℃
6. Temperature control accuracy: ±1℃
7. Timing range: 0-99h59min59s
8. Complete machine noise≤65dB (A)
9. Power supply / total power: Ac220V 50Hz 20A/2200W
10. Net weight:140KG
11. Overall dimension: 760mm×590mm×830mm (L×W×H)
Adaptive rotor:
Rotor number |
name |
Rotor capacity |
maximum speed |
Maximum relative centrifugal force |
Centrifuge tube size (mm) |
01 |
Angle rotor |
10×5ml (without cover) |
22000r/min |
35713×g |
φ13×51-53 |
02 |
Angle rotor |
12×5ml |
20000r/min |
31300×g |
φ13×51-53 |
03 |
Angle rotor |
24×1.5/2.2ml |
18000r/min |
29703×g |
φ10×42 |
04 |
Angle rotor |
8×15ml |
16000r/min |
27190×g |
φ16×118 |
0401 |
adapter |
8×10ml |
16000r/min |
27190×g |
φ16×81 |
05 |
Angle rotor |
48×1.5/2.2ml |
16000r/min |
26617×g |
φ10×42 |
06 |
Angle rotor |
12×10ml |
17000r/min |
27464×g |
φ16×81 |
0601 |
adapter |
12×5ml |
17000r/min |
27464×g |
φ13×51-53 |
07 |
Angle rotor |
12×15ml |
15000r/min |
24903×g |
φ16×118 |
08 |
Angle rotor |
6×50ml (round bottom) |
17000r/min |
29080×g |
φ28x103 (straight port) |
0801 |
adapter |
6×10ml (round bottom) |
17000r/min |
29080×g |
φ16×101 |
09 |
Angle rotor |
6×50ml (tip bottom / round bottom) |
15000r/min |
29700×g |
φ 28x116 |
0901 |
adapter |
6×10ml (round bottom) |
15000r/min |
29700×g |
φ16×101 |
0902 |
adapter |
6×15ml (tip bottom) |
15000r/min |
29700×g |
φ16×118 |
10 |
Angle rotor |
8×50ml (tip bottom / round bottom) |
13000r/min |
23050×g |
φ 28x116 |
1001 |
adapter |
8×10ml |
13000r/min |
23050×g |
φ16×101 |
11 |
Angle rotor |
6×100ml (round bottom) |
12000r/min |
21250×g |
φ38x103 |
1101 |
adapter |
6×50ml (round bottom) |
12000r/min |
21250×g |
φ 28x103 |
1102 |
adapter |
6×10ml (round bottom) |
12000r/min |
21250×g |
φ16×101 |
12 |
Angle rotor |
4×250ml (flat-bottom round cup) |
13000r/min |
23050×g |
/ |
1201 |
adapter |
4×100ml (round bottom) |
12000r/min |
23050×g |
φ38x103 |
1202 |
adapter |
4×50ml (round bottom) |
12000r/min |
23050×g |
φ 28x103 |
13 |
Horizontal rotor |
4×250ml (flat-bottom round cup) |
4500r/min |
3049×g |
φ 61.5× 126 |
1301 |
adapter |
36×5ml / 2ml (blood collection vessel) |
4500r/min |
3800×g |
φ13×75-100 |
1302 |
adapter |
36×1.5/2.2ml |
4500r/min |
3800×g |
φ10×42 |
1303 |
adapter |
20×15ml/10ml |
4500r/min |
3800×g |
φ16×100-120 |
1304 |
adapter |
4×50ml |
4500r/min |
3800×g |
φ29×106-107 |
1305 |
adapter |
4×100ml |
4500r/min |
3800×g |
φ38×113-118 |
14 |
Horizontal rotor |
4×300ml (square cup) |
4000r/min |
2980×g |
Configure the adapter (required) |
1401 |
adapter |
48×5ml / 2ml (auto-removal) |
4000r/min |
2980×g |
φ13×75-100 |
1402 |
adapter |
48×1.5ml/2.2ml |
4000r/min |
2980×g |
φ10×42 |
1403 |
adapter |
24×15ml/10ml |
4000r/min |
2980×g |
φ16×100-120 |
1404 |
adapter |
8×50ml |
4000r/min |
2980×g |
φ29×106-107 |
1405 |
adapter |
4×100ml |
4000r/min |
2980×g |
φ38×113-118 |
1304 |
adapter |
4×50ml |
4500r/min |
3800×g |
φ29×106-107 |
1305 |
adapter |
4×100ml |
4500r/min |
3800×g |
φ38×113-118 |
15 |
Horizontal rotor |
4×400ml (square cup) |
4000r/min |
2980×g |
Configure the adapter (required) |
1501 |
adapter |
64×5ml / 2ml (self-stripping of collecting vessel) |
4000r/min |
2980×g |
φ13×75-100 |
1502 |
adapter |
64×1.5ml/2.2ml |
4000r/min |
2980×g |
φ10×42 |
1503 |
adapter |
36×15ml/10ml |
4000r/min |
2980×g |
φ16×100-120 |
1504 |
adapter |
16×50ml |
4000r/min |
2980×g |
φ29×106-107 |
1505 |
adapter |
4×100ml |
4000r/min |
2980×g |
φ38×113-118 |
16 |
Horizontal rotor |
4×500ml (flat-bottom round cup) |
4000r/min |
3480×g |
φ79×137 |
1601 |
adapter |
68×5ml / 2ml (blood collection vessel) |
4000r/min |
3480×g |
φ13×75-100 |
1602 |
adapter |
68×1.5ml/2.2ml |
4000r/min |
3480×g |
φ10×42 |
1603 |
adapter |
32×15 / 10ml (round bottom / pointed bottom) |
4000r/min |
3480×g |
φ16×100-120 |
1604 |
adapter |
12×50ml (round bottom) |
4000r/min |
3480×g |
φ29×106-107 |
1605 |
adapter |
4×100ml (round bottom) |
4000r/min |
3480×g |
φ38×113-118 |
1606 |
adapter |
4×250ml |
4000r/min |
3480×g |
φ61.5×126 |
17 |
Horizontal rotor |
4×500ml (square cup) |
4000r/min |
2910×g |
Configuring the adapter (required) |
1701 |
adapter |
80×5ml / 2ml (auto-removal) |
4000r/min |
2910×g |
φ13×75-100 |
1702 |
adapter |
80×1.5ml/2.2ml |
4000r/min |
2910×g |
φ10×42 |
1703 |
adapter |
48×15ml/10ml |
4000r/min |
2910×g |
φ16×100-120 |
1704 |
adapter |
20×50ml |
4000r/min |
2910×g |
φ29×106-107 |
1705 |
adapter |
8×100ml |
4000r/min |
2910×g |
φ38×113-118 |
18 |
Horizontal rotor |
4×600ml (square cup) |
4000r/min |
3480×g |
Configuring the adapter (required) |
1801 |
adapter |
100×5ml / 2ml (extraction vessel) |
4000r/min |
3480×g |
φ13×75-100 |
1802 |
adapter |
100×1.5ml/2.2ml |
4000r/min |
3480×g |
φ10×42 |
1803 |
adapter |
48×15ml/10ml |
4000r/min |
3480×g |
φ16×100-120 |
1804 |
adapter |
20×50ml |
4000r/min |
3480×g |
φ29×106-107 |
1805 |
adapter |
16×100ml |
4000r/min |
3480×g |
φ38×113-118 |
19 |
Horizontal rotor |
4×750ml (flat-bottom round cup) |
4000r/min |
3578×g |
φ98×140 |
1901 |
adapter |
104×5ml / 2ml (blood collection) |
4000r/min |
3578×g |
φ13×75-100 |
1902 |
adapter |
104×1.5ml/2.2ml |
4000r/min |
3578×g |
φ10×42 |
1903 |
adapter |
52×15/10ml |
4000r/min |
3578×g |
φ16×100-120 |
1904 |
adapter |
20×50ml |
4000r/min |
3578×g |
φ29×106-107 |
1905 |
adapter |
12×100ml |
4000r/min |
3578×g |
φ38×113-118 |
1906 |
adapter |
4×250ml |
4000r/min |
3578×g |
φ61.5×126 |
1907 |
adapter |
4×500ml |
4000r/min |
3578×g |
φ79×137 |
20 |
Horizontal rotor |
4×2×96-well (microplate) |
4000r/min |
2978×g |
125×85×16.2 |