Application area:
It is suitable for molecular biology, protein, DNA, RNA, blood component separation and cell component separation, and is widely used in clinical medicine, life science, bioengineering, biochemistry, medical research, agriculture and animal husbandry, biopharmaceutical and other fields
Product features:
● Steel body, large torque brushless AC frequency conversion motor drive: no toner pollution, low noise, small vibration, high speed control precision
● Large color screen interface display, touch control, easy to operate.
● Built-in 10 kinds of up / down rate gear, gear can be customized according to the experimental requirements, to ensure that the centrifugal effect is good.
● Clever cooling air duct design technology, effectively control the chamber temperature increase in the centrifugal process.
● Can not only high-speed centrifugation (21000 r/min), but also can large capacity centrifugation (4x750ml), one machine multi-function.
● With the door cover, misoperation and other diagnostic functions, the machine can directly display the fault information, easy to judge and repair, to ensure the safety of man-machine
Company Name :
Hunan Anjunyan Instruments Co., Ltd.Brand :
ANJUNYANTechnical parameter:
1. Maximum rotation speed: 21,000r/min
2. Maximum centrifugal force: 32,540×g
3. Maximum capacity: 4×750ml
4. Speed accuracy: ±10r/min
7. Timing range: 0-99min59s
8. Complete machine noise≤60dB (A)
9. Power supply/total power: Ac220V 50Hz 10A/770W
10. Net weight: 50KG
11. Overall dimension: 640mm×480mm×370mm(L×W×H)
Adaptive rotor:
Rotor number |
name |
Rotor capacity |
maximum speed |
Maximum relative centrifugal force |
Centrifuge tube size (mm) |
01 |
Angle rotor |
12×1.5/2.2ml (without cover) |
21000r/min |
30700×g |
φ10×42 |
02 |
Angle rotor |
10×5ml (without cover) |
21000r/min |
32540×g |
φ13×51-53 |
03 |
Angle rotor |
12×5ml |
18000r/min |
25356×g |
φ13×51-53 |
0301 |
adapter |
12×1.5ml |
18000r/min |
25356×g |
φ10×42 |
04 |
Angle rotor |
8×(8×0.2mlpcr) (without a cover) |
16000r/min |
24614×g |
φ6.2×22 |
05 |
Angle rotor |
24×1.5/2.2ml |
15000r/min |
20627×g |
φ10×42 |
06 |
Angle rotor |
36×1.5/2.2ml |
15000r/min |
23394×g |
φ10×42 |
07 |
Angle rotor |
48×1.5/2.2ml |
15000r/min |
21400×g |
φ10×42 |
08 |
Angle rotor |
48×0.5ml |
15000r/min |
21400×g |
φ8×32 |
09 |
Angle rotor |
12×10ml |
15000r/min |
21400×g |
φ16×81 |
0901 |
adapter |
12×5ml |
12000r/min |
17390×g |
φ13×51-53 |
10 |
Angle rotor |
8×15ml |
15000r/min |
15500×g |
φ16×118 |
1001 |
adapter |
8×10ml |
15000r/min |
15500×g |
φ16×81 |
1002 |
adapter |
8×5ml |
15000r/min |
15500×g |
φ13×51-53 |
11 |
Angle rotor |
12×15ml |
13000r/min |
18705×g |
φ16×118 |
12 |
Angle rotor |
6×50ml (tip bottom / round bottom) |
14000r/min |
20220×g |
φ 28x116 |
1201 |
adapter |
6×10ml (round bottom) |
14000r/min |
20220×g |
φ16×101 |
1202 |
adapter |
6×15ml (tip bottom) |
14000r/min |
20220×g |
φ16×118 |
13 |
Angle rotor |
4×100ml (round bottom) |
13000r/min |
18138×g |
φ38x103 |
1301 |
adapter |
4×50ml (round bottom) |
13000r/min |
18138×g |
φ 28x103 |
14 |
Angle rotor |
8×50ml (tip bottom / round bottom) |
13000r/min |
19650×g |
φ 28x116 |
1401 |
adapter |
8×15ml |
13000r/min |
19650×g |
φ16×101 |
1402 |
adapter |
8×10ml |
13000r/min |
19650×g |
φ16×118 |
15 |
Angle rotor |
6×100ml (round bottom) |
11000r/min |
14610×g |
φ38x103 |
1501 |
adapter |
6×50ml (round bottom) |
11000r/min |
14610×g |
φ 28x103 |
1502 |
adapter |
6×10ml (round bottom) |
11000r/min |
14610×g |
φ16×101 |
16 |
Horizontal rotor |
4×250ml (flat-bottom round cup) |
4000r/min |
3049×g |
φ 61.5× 126 |
1601 |
adapter |
36×5ml / 2ml (blood collection vessel) |
4000r/min |
3049×g |
φ13×75-100 |
1602 |
adapter |
36×1.5/2.2ml |
4000r/min |
3049×g |
φ10×42 |
1603 |
adapter |
20×15ml/10ml |
4000r/min |
3049×g |
φ16×100-120 |
1604 |
adapter |
4×50ml |
4000r/min |
3049×g |
φ29×106-107 |
17 |
Horizontal rotor |
4×300ml (square cup) |
4000r/min |
2980×g |
Configure the adapter (required) |
1701 |
adapter |
48×5ml / 2ml (auto-removal) |
4000r/min |
2980×g |
φ13×75-100 |
1702 |
adapter |
48×1.5ml/2.2ml |
4000r/min |
2980×g |
φ10×42 |
1703 |
adapter |
24×15ml/10ml |
4000r/min |
2980×g |
φ16×100-120 |
1704 |
adapter |
8×50ml |
4000r/min |
2980×g |
φ29×106-107 |
18 |
Horizontal rotor |
4×400ml (square cup) |
4000r/min |
2980×g |
Configure the adapter (required) |
1801 |
adapter |
64×5ml / 2ml (self-stripping of collecting vessel) |
4000r/min |
2980×g |
φ13×75-100 |
1802 |
adapter |
64×1.5ml/2.2ml |
4000r/min |
2980×g |
φ10×42 |
1803 |
adapter |
36×15ml/10ml |
4000r/min |
2980×g |
φ16×100-120 |
1804 |
adapter |
16×50ml |
4000r/min |
2980×g |
φ29×106-107 |
19 |
Horizontal rotor |
4×500ml (flat-bottom round cup) |
4000r/min |
3480×g |
Configure the adapter (required) |
1901 |
adapter |
68×5ml / 2ml (blood collection vessel) |
4000r/min |
3480×g |
φ13×75-100 |
1902 |
adapter |
32×15 / 10ml (round bottom / pointed bottom) |
4000r/min |
3480×g |
φ16×100-120 |
1903 |
adapter |
12×50ml (round bottom) |
4000r/min |
3480×g |
φ29×106-107 |
1904 |
adapter |
4×100ml (round bottom) |
4000r/min |
3480×g |
φ38×113-118 |
20 |
Horizontal rotor |
4×600ml (square cup) |
4000r/min |
3480×g |
Configure the adapter (required) |
2002 |
adapter |
100×5ml / 2ml (extraction vessel) |
4000r/min |
3480×g |
φ13×75-100 |
2003 |
adapter |
100×1.5ml/2.2ml |
4000r/min |
3300×g |
φ10×42 |
2004 |
adapter |
48×15ml/10ml |
4000r/min |
3480×g |
φ16×100-120 |
2005 |
adapter |
20×50ml |
4000r/min |
3480×g |
φ29×106-107 |
2006 |
adapter |
16×100ml |
4000r/min |
3400×g |
φ38×113-118 |
21 |
Horizontal rotor |
4×750ml (flat-bottom round cup) |
4000r/min |
3578×g |
φ98×140 |
2101 |
adapter |
104×5ml / 2ml (blood collection) |
4000r/min |
3578×g |
φ13×75-100 |
2102 |
adapter |
104×1.5ml/2.2ml |
4000r/min |
3578×g |
φ10×42 |
2103 |
adapter |
52×15/10ml |
4000r/min |
3578×g |
φ16×100-120 |
2104 |
adapter |
20×50ml |
4000r/min |
3578×g |
φ29×106-107 |
2105 |
adapter |
12×100ml |
4000r/min |
3578×g |
φ38×113-118 |
22 |
Horizontal rotor |
2×2×96-well (microplate) |
4200r/min |
3060×g |
125×85×16.2 |